LP6 Ventilator

LP6 Ventilator
LP6 Ventilator
Send Inquiry
Product Code : JLab1326
Brand Name : JLab
Price And Quantity
  • Minimum Order Quantity
  • 1 EA
Product Description

LP6 Ventilator

  • Mode: Standby, Assist/Control, SIMV or Pressure Cycle 
  • Low Pressure Alarm: Set limit for Low Pressure alarm 2 to 32 
  • cmH2O in increments of 2 cmH2O
  • High Pressure Alarm Limit: (Assist/Control, SIMV Modes) or limit for Pressure Cycle mode: 15 to 90 cmH2O in increments of 5 cmH2O
  • Volume: Push-to-turn knob: 100 to 2200 mL
  • Breath Rate: 1 to 20 BPM in increments of 1 BPM and 22 to 38 BPM in increments of 2 BPM
  • Inspiratory Time: 0.5 to1.0 sec in increments of 0.1 sec; 1.2 sec; and 1.5 to 5.5 sec in increments of 0.5 sec
  • Breathing Effort: Push-to-turn knob sets pressure level to detect breathing effort (-10 cmH2O/hPa to +10 cmH2O)

 Specifications:

Front Panel Input

Patient Pressure: Port for connection to proximal pressure line of 
patient circuit

Front Panel Output

Patient Air: 22 mm x 15 mm tube for connection to bacteria filter
Exhalation Valve: Port for connection to exhalation valve 
of patient circuit

Indicators, Normal Events 

Patient Pressure Meter: Displays patient pressure -10 to +100 cmH2O; can 
also display battery charge and machine hrs of operation
Breathing Effort: Green LED activated by adequate patient breathing effort
Power: LEDs indicate operating power source: green AC Pwr/Batt 
Chg, amber External Battery, flashing amber Internal Battery
Alarms: Flashing red LEDs: Low Pressure/Apnea, Low Power, 
High Pressure, Setting Error, Power Switchover 

Audible Alarms

Pulsating Tone: Low Pressure/Apnea; Low Power, High Pressure, 
Setting Error, Power Switchover 
Steady Tone: Loss of microprocessor control
Reminder Tone: Every 5 mins when powered by Internal Battery, 
each time accessory printer generates report

Rear Panel Controls

AC Circuit Breaker: Internal to AC power switch
(1 for ON; 0 for OFF)

Rear Panel Inputs

Inlet Filter: Intake for patient air; screw off cap for filter change
External Battery: Connection for 12 
VDC battery Communication Port: Calibration information 
during service procedure 





Trade Information
  • FOB Port
  • Mumbai
  • Payment Terms
  • Paypal, Western Union, Telegraphic Transfer (T/T), Letter of Credit at Sight (Sight L/C), Letter of Credit (L/C), Delivery Point (DP), Days after Acceptance (DA), Cash Advance (CA), Cash on Delivery (COD), Cash Against Delivery (CAD)
  • Supply Ability
  • 1000 EA Per Week
  • Delivery Time
  • 7 Days
  • Sample Available
  • Yes
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Packaging Details
  • Packed in a case.
  • Main Export Market(s)
  • Africa, Middle East, Western Europe, Eastern Europe, South America, North America, Central America, Australia, Asia
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, ISO, 14001, CE
X